  광 계측기기 (OPTICAL INSTRUMENTS)  

 

 

 

 

 

 

 

 

IL1400A RADIOMETER / PHOTOMETER

 

  • 7 Decade DynamicRange
  • 0.2% LInearity
  • 20 Decade Dose Integration Range
  • Smart Detectors
  • Direct Reading in any Optical Units
  • User-Friendly Alphanumeric Display
  • Darkroom Hold Button
  • Simple Operating Buttons
  • Hand Held - Completely Portable
  • Battery Operated
  • Analog Recorder Output (0-1 volt)
  • Optional Printer / Computer Port
  • Automatic Zeroing
  • Automatic Ranging
  • Automatic Shutoff

 

 

 

Front Panel Controls:

Programmable Features:

The 'ZERO' button allows the automatic subtraction of any undesired background light. This convenient function is necessary for accurate readings, since ambient and scattered light can contribute significantly to the overall reading.

The 'SIGNAL' button selects direct measurement mode, including automatically selected range and units. This operating mode is used for measuring the instantaneous intensity of a light source, with the reading updated every 1/2 second, autoranging over a seven decade dynamic range.

The 'INTEGRATE' button alternately selects between two 5 decade dynamic range integration modes, 'HI' and 'LO', also with auto-ranging and auto-units. Integration is used to measure the 'dose' or sum of all light reaching the detector over time. The IL1400A is capable of exposure integrations of up to 24 hours in duration.

The 'HOLD' button freezes the display to hold darkroom readings or to terminate / pause an exposure integration.
This feature makes it much more convenient to take readings in the dark. Pressing the 'HOLD' button also tells the computer to send data to the optional TTL printer.

The 'ON/OFF' button is complemented by an automatic shut-off feature for prolonged battery life, which can be optionally defeated for special long duration measurements.

The 32 character alphanumeric LCD continuously displays data with full units and the present mode of operation.
Easy to understand messages such as 'LOW BATTERY' and 'over range' also appear to indicate error situations, and to guide the user through the program mode.

The menu driven Programming Mode allows experienced users to customize many of the IL1400A's features. The auto shut-off can be optionally defeated in this mode (temporarily or permanently) for long duration measurements.

The preprogrammed units and calibration factor can also be changed in this mode, allowing custom recalibration to a relative standard, or conversion to a different set of units. The IL1400A stores the new calibration and units information in the individual detector's internal memory.

The original N.I.S.T. traceable calibration information is stored permanently in a view-only menu screen, that cannot be altered by the user. The individual detector's serial number, manufacture date, most recent calibration date, and range limitations can also be viewed in the program mode.

 

ELECTRICAL / MECHANICAL:

Dynamic Range: 10 pA to 350 uA.
Input Impedance: Virtual ground (summing node of op-amp).
Linearity: ±0.2%, ±1 digit on low end.
Input Power: 4 'AA' alkaline batteries, 26 mA, battery eliminator available as an option.
Battery Life: 36 hours continuous operation.
TTL Output: 0 to 5 volts.
Recorder Output: 408 Ω impedance, 100 to 1000 mV, ranging every decade, current limited.
Size: 185 mm x 100 mm x 43 mm (7.3" x 3.9" x 1.7").
Weight: 0.55 kg (1.2 lbs.).

 

 

광량계, IL1700, IL1400, uv curing, radiometer, 경화, 자외선, 적외선, 근적외선, 원적외선, 가시광선, 건조, 화학방사선, 세정, 살균, 수처리, 태양광, 복사량측정, 광량계, 조도계, 광도계, 센서, 스펙트로메타, 라디오메타, 포토메타, 스펙트로라디오메타, uv, LED, 자외선측정, UV광량, IL393, IL290, LZ393, IL393, ILT400, ILT490, ILT1700, ILT1400, ILT900, ILT900 LED, 색차계,조사, 분광, 스펙트럼, 분석, 복사도, 환경, 생화학, 광생물학, 레이저,

ultraviolet radiation, uv meter, light bugs, UVA, UV-b, UV-A, UVB, UVC, UV-Cil290a, il390c, il393, uv exposure,

노광, spot irradiance measurements, il1747, il1447, il1745, il1445, pir irradiance calibration,

photometry, photometer system, photometric illuminance, flash photometer, radiometer, high gain lens, flash sources, flash effective intensity, il1710, il1410, il1711, il1715, radiometer, visible, near-ir, irradiance measurements, radiometry, spatial response, uv detection, radiance measurements, irradiance detector, nist traceable, il1705, il1405, il1715, photometer system, photoresist, a response, b response, uv measurement, blue visible irradiance, exposing photoresist, uva, photoresist equipment, radiometer, uv sensitivity, il1740a

 

Top of Page

 

 

   

DTX logo

경기도 시흥시 정왕동 1288-2 번지 동우디지털파크 A-512 |   E-mail : contact@dtx.co.kr  

Tel : 031-497-1134 (代)   |  Fax : 031-497-1138   |  All Rights Reserved, Copyright (C) DTX, INC. 2008

Tel : 031-419-6770 (영업부 직통)   |   Internet Fax : 0505-497-7710